Home > Cannot Locate > Cannot Locate Document Specification Because Multiple Schemas Matched The Message

Cannot Locate Document Specification Because Multiple Schemas Matched The Message

Make sure the system which is generating the message writes this namespace. I have created several samples to show how it works. If we could limit the schema visibility inside the application boundaries, creating the BizTalk applications for consuming both service versions would be simple. The error is raised if more than one schemas with this MessageType is found. http://ecoflashapps.com/cannot-locate/cannot-locate-document-specification-because-multiple-schemas-matched.html

Note: The samples above are about the XMLReceive pipeline, but the same  “schema uniqueness” rule works also for the XMLTransmit send pipeline. “Schema Uniqueness” Rule The MessageType schema should be unique within the BizTalk Service This will solve the schema conflict issue. Wednesday, December 17, 2014 10:35 AM Reply | Quote Answers 0 Sign in to vote I am having application A - working fine. Thank you Tuesday, January 04, 2011 10:11 PM Reply | Quote 0 Sign in to vote I was stuck on this as well. https://social.msdn.microsoft.com/Forums/en-US/a6212aec-06cd-4164-b6fe-469a02da7b80/errorcannot-locate-document-specification-because-multiple-schemas-matched-the-message-type?forum=biztalkgeneral

There is on way around this. I've seen so many of these errors posted on the newsgroups that I thought I'd mention this as a possible cause.If you are using test harnesses coupled with web services be Cloud Based or Install Inhouse You can access the service via our web site for a small monthly subscription price, or install it on your own Microsoft servers inhouse. So the schemas are now placed in different applications but it doesn't change the schema visibility.

Post Categories installer assembly gac global assembly cache .net windows server 2008 gacutil command line dos Archives May 2015 (1) April 2015 (1) March 2015 (2) February 2015 (1) December 2014 If 2 schemas with the same MessageType(RootName#NameSpace) has been deployed, the XMLDisassembler will not understand which schematype the received message is of.So the exception "Cannot locate document specification because multiple schemas matched the Do we have to take care of this schema if we consume several WCF services? i could easily understand the error is due to the same object name in both databases because other application is already using the message type.

I suppose I sould have created 2 Receive Pipelines so that I could specifically designate which schema was to be used, but your solution was faster and solved the problem. Solution Number Two: One solution is that if we are using xml Receive then in the pipeline definition at receive location level, set the “Allow Unrecognized Documents” to true. Hope this helps.Greetings,HTH Naushad Alam When you see answers and helpful posts, please click Vote As Helpful, Propose As Answer, and/or Mark As Answer alamnaushad.wordpress.com Wednesday, December 17, 2014 2:36 PM https://srirambiztalks.wordpress.com/2011/03/24/cannot-locate-document-specification-because-multiple-schemas-matched-the-message-type/ Join them; it only takes a minute: Sign up BizTalk with BTARN: Cannot locate document specification because multiple schemas matched the message type “string” up vote 2 down vote favorite We

The message which you are sending to BizTalk should have http://ProjectNameSync.CRMCommonResponse as namespace and Response as root name. When I dropped a test file there was no error. But both Imorting schemas are identical. Alternatively, I can create a new Application in Biztalk and Import the schemas dll as a resource, but then when I deploy my 2 projects that contain references to the schemas

Is the “schema uniqueness” rule relating to the imported schemas? this page Nothing else is in this application. Pretty simple, right?Well, no. It enforces your organisation’s rules, such as minimum lunch, daily start and end times, maximum accrued deficits and surpluses.

delete the newly created record from BT.DocumentSpec table . navigate here asked 11 months ago viewed 285 times active 11 months ago Upcoming Events 2016 Community Moderator Election ends Nov 22 Related 0cannot retrive a document specification using this name1The %SourceFileName% macro This was technically accurate but rather frustrating to find. from where I will get schema type ?

You need to look through your deployed schemas and find out what assemblies/applications have duplicate MessageTypes with Root Name string. Record Working Time, Sickness and Leave A central place to store all of your staffs' working hours, holiday and sickness and flexi time leave. In this way we can exclude this exception. Check This Out An important note is the schema uniqueness rule is not verified at the deployment time.

Learning resources Microsoft Virtual Academy Channel 9 MSDN Magazine Community Forums Blogs Codeplex Support Self support Programs BizSpark (for startups) Microsoft Imagine (for students) United States (English) Newsletter Privacy & cookies An error is raised if the MessageType is not found. from where I will get the schema assembly full name ???Any help is welcome.

it works !!

Biztalkien Leonid Ganeline - Microsoft BizTalk Server & Integration search for term Home Contact Syndication Login News Tag Cloud Answers BizTalk Debugging ESB Subversion TFS WCF more tags... Proposed as answer by Mohan Raj Aryal Thursday, December 18, 2014 4:05 AM Marked as answer by Angie xuMicrosoft contingent staff, Moderator Thursday, December 25, 2014 1:42 AM Wednesday, December 17, generally when i get this error ,I try to look for the duplicate schema under Application Artifacts , delete it if it is not required. Copyright © Leonid Ganeline [email protected] +44 (0)1924 918 177 Trial Registration Sign in About Flexplanner What is Flexitime?

Leave Calendar & Holiday Approvals Store annual leave calendars for your teams, and handle holiday requests. It is the same schema almost in each and every WCF service. hence it is important to keep the message type unique across different schemas...   If your target applications are expecting same root node and namespace for both messages, I feel it http://ecoflashapps.com/cannot-locate/cannot-locate-document-specification-because-multiple-schemas.html Try the above given solution to solve your problem.

This error occurs: Microsoft.BizTalk.Component.XmlAsmException: C0C01306: Cannot locate document specification because multiple schemas matched the message type "string". In this time Microsoft decided do not change the XMLReceive and XMLTransmit pipelines to embrace new application conception and since then this feature was not on the priority list in the See our Clients page for more. All rights reserved.Newsletter|Contact Us|Privacy Statement|Terms of Use|Trademarks|Site Feedback srirambiztalks Katradhu Kaialavu,Kalladhadhu Ulagalavu!

Ask a question Quick access Forums home Browse forums users FAQ Search related threads Remove From My Forums Answered by: Error:Cannot locate document specification because multiple schemas matched the message type. The software enables employees to record time worked via an easy-to-use web interface and ensures staff do not falsify their working hours. at Microsoft.BizTalk.Component.XmlAsmStreamWrapper.Read(Byte[] buffer, Int32 offset, Int32 count) at System.Xml.XmlTextReaderImpl.InitStreamInput(Uri baseUri, String baseUriStr, Stream stream, Byte[] bytes, Int32 byteCount, Encoding encoding) at System.Xml.XmlTextReaderImpl.FinishInitStream() at System.Xml.XmlReaderSettings.CreateReader(Stream input, Uri baseUri, String baseUriString, XmlParserContext inputContext) The content you requested has been removed.

Contact Please contact us by email or phone at the below. Privacy statement Help us improve MSDN. The BizTalk receives messages on the Receive Locations. In this case a message should be received in the well-known format.

But your input xml could be missing "". so when i start the orchestartion and test the application i get error There was a failure executing the response(receive) pipeline: "Microsoft.BizTalk.DefaultPipelines.XMLReceive, Microsoft.BizTalk.DefaultPipelines, Version=3.0.1.0, Culture=neutral, PublicKeyToken=4FbH8369ad789B92" Source: "XML disassembler" Send Port: These samples are bare-bone projects, focused on the “schema uniqueness” rule. Thursday, December 22, 2005 "multiple schemas match the message type"may be caused by web services I was stuck recently with what seemed like a pair of contradictory errors.I had an application

You have to either use a different BizTalk Group or rename everything, .Net Types, Schema namespaces, etc. And value of “Assembly” field which will give you the, Separate these values by a comma as , . If this answers your question please mark it accordingly. Looks like a reason for this “schema uniqueness” rule is simple.

Reason 11 Holiday approval processes The system handles all your annual leave approvals, by enabling managers to view and approve the holiday requests from their team . Easier way to add a DLL to the GAC BizTalk exception handling with web services Solving BizTalk "error X2044" ► November (1) Labels biztalk Mapper documentation Web Services XSLT books error To get this Goto your BizTalk admin console, select your application, select the “Schema” folderSelect the schema for which you want to get the schema full name, right click on it